[{"data":1,"prerenderedAt":752},["ShallowReactive",2],{"catalog:meta":3,"guides:page:\u002Finjection-molding-machine-parts\u002Fheaters\u002Freplacing-heater-bands:*":258,"guides:topics:heaters:\u002Finjection-molding-machine-parts\u002Fheaters\u002Freplacing-heater-bands:path,title,short":540,"guides:page:\u002Finjection-molding-machine-parts\u002Fheaters:diagram":561,"diagram:id:barrel-heating":563,"catalog:parts::EC-HT-01,MC-GMP-02":737},{"categories":4,"machines":132,"zones":212,"totals":255},[5,35,59,122],{"id":6,"name":7,"slug":8,"description":9,"partCount":10,"subcategories":11},"EC","Electrical Components","electrical","Electrical systems and components for injection molding machines including heaters, thermocouples, servo motors, and controllers.",11,[12,17,22,27,31],{"id":13,"name":14,"slug":15,"partCount":16},"EC-CBC","Circuit Boards & Controllers","circuit-boards",4,{"id":18,"name":19,"slug":20,"partCount":21},"EC-CE","Connectors & Cables","connectors-cables",2,{"id":23,"name":24,"slug":25,"partCount":26},"EC-GEP","Servo Motors & Drives","servo-motors",1,{"id":28,"name":29,"slug":30,"partCount":21},"EC-HT","Heaters","heaters",{"id":32,"name":33,"slug":34,"partCount":21},"EC-SF","Safety Components","safety",{"id":36,"name":37,"slug":38,"description":39,"partCount":40,"subcategories":41},"HY","Hydraulic Components","hydraulic","Complete range of hydraulic system components including pumps, valves, motors, and pressure controls for injection molding machines.",14,[42,46,51,55],{"id":43,"name":44,"slug":45,"partCount":26},"HY-AU","Accumulators","accumulators",{"id":47,"name":48,"slug":49,"partCount":50},"HY-CV","Control Valves","control-valves",6,{"id":52,"name":53,"slug":54,"partCount":26},"HY-MO","Monitors & Gauges","monitors-gauges",{"id":56,"name":57,"slug":58,"partCount":50},"HY-PW","Pumps & Motors","pumps-motors",{"id":60,"name":61,"slug":62,"description":63,"partCount":64,"subcategories":65},"MC","Mechanical Components","mechanical","Mechanical parts and assemblies including barrels, screws, tie bars, bushings, platens, and clamping components.",42,[66,71,75,80,85,89,93,97,101,105,109,114,118],{"id":67,"name":68,"slug":69,"partCount":70},"MC-BC","Barrels & Cylinders","barrels-cylinders",5,{"id":72,"name":73,"slug":74,"partCount":16},"MC-SB","Screw Barrels & Seals","screws",{"id":76,"name":77,"slug":78,"partCount":79},"MC-TC","Tie Bars & Columns","tie-bars",7,{"id":81,"name":82,"slug":83,"partCount":84},"MC-GZ","Bushings & Guides","bushings-guides",8,{"id":86,"name":87,"slug":88,"partCount":26},"MC-PP","Platens","platens",{"id":90,"name":91,"slug":92,"partCount":70},"MC-TL","Toggle & Links","toggle-links",{"id":94,"name":95,"slug":96,"partCount":21},"MC-CC","Clamping Components","clamping",{"id":98,"name":99,"slug":100,"partCount":21},"MC-GMP","Tools & Accessories","tools-accessories",{"id":102,"name":103,"slug":104,"partCount":21},"MC-ES","End Caps & Plates","end-caps",{"id":106,"name":107,"slug":108,"partCount":26},"MC-SR","Seals & Rings","seals-rings",{"id":110,"name":111,"slug":112,"partCount":113},"MC-JM","Joints & Mounts","joints-mounts",3,{"id":115,"name":116,"slug":117,"partCount":26},"MC-SG","Safety Guards","safety-guards",{"id":119,"name":120,"slug":121,"partCount":26},"MC-CR","Clamping Mechanism","clamping-mechanism",{"id":123,"name":124,"slug":125,"description":126,"partCount":113,"subcategories":127},"O","Other Components","other","Additional components including filters, cooling systems, lubrication parts, and other auxiliary equipment.",[128],{"id":129,"name":130,"slug":131,"partCount":113},"O-TC","Filters & Cooling","filters-cooling",[133,143,161,172,180,188,194,200,205],{"id":134,"name":135,"slug":134,"series":136,"partCount":142},"haitian","Haitian International",[137,138,139,140,141],"Mars Series (MA)","Jupiter Series (JU)","Zhafir Venus Series (VE)","Zhafir Zeres Series (ZE)","Zhafir Jeres Series (JE)",68,{"id":144,"name":145,"slug":144,"series":146,"partCount":160},"yizumi","Yizumi",[147,148,149,150,151,152,153,154,155,156,157,158,159],"A6 Series","A5-EU Series","A5-N Series","SKIII Series","DP Series","D1 Series","FF Series","FF-M Series","P Series","CG-P Series","VM Series","SPET Series","LSR Series",12,{"id":162,"name":163,"slug":162,"series":164,"partCount":171},"chen-hsong","Chen Hsong",[165,166,167,168,169,170],"JETMASTER MK Series","JETMASTER SVP Series","SUPERMASTER Series","EASYMASTER Series","SPARK Series","JETMASTER C2 Series",10,{"id":173,"name":174,"slug":173,"series":175,"partCount":179},"tederic","Tederic",[176,177,178],"NEO Series","D Series (Two-Platen)","DE Series (All-Electric)",0,{"id":181,"name":182,"slug":181,"series":183,"partCount":179},"borch","Borch",[184,185,186,187],"BU Series (Two-Platen)","BS-III Series (Servo)","BE Series (All-Electric)","BM Series (Multi-color)",{"id":189,"name":190,"slug":189,"series":191,"partCount":179},"log-machine","LOG Machine",[192,193],"LOG-SE Series","LOG-EE Series (All-Electric)",{"id":195,"name":196,"slug":195,"series":197,"partCount":179},"donghua","Donghua",[198,199],"DH Series (Servo)","DH-TP Series (Two-Platen)",{"id":201,"name":202,"slug":201,"series":203,"partCount":179},"sunbun","Sunbun",[204],"Sunbun Servo Series",{"id":206,"name":207,"slug":206,"series":208,"partCount":179},"lijin","L.K. Machinery (Lijin)",[209,210,211],"POTENZA Series","FORZA Series (Two-Platen)","ELETTRICA Series (All-Electric)",[213,217,221,225,228,231,235,238,242,248,251],{"id":214,"number":26,"name":215,"role":216,"partCount":21},"clamp-cylinder","Clamping cylinder","The hydraulic cylinder behind the rear platen. It drives the crosshead that straightens the toggle links, which opens and closes the mold and builds the clamping force.",{"id":218,"number":21,"name":219,"role":220,"partCount":50},"toggle","Toggle mechanism","Links, pins and bushings between the rear and moving platens. They multiply the force of the clamping cylinder and lock the mold shut while plastic is injected.",{"id":222,"number":113,"name":223,"role":224,"partCount":113},"ejector","Ejector","A small cylinder behind the moving platen that pushes the ejector rods and plate forward to release the finished part from the mold.",{"id":78,"number":16,"name":226,"role":227,"partCount":40},"Tie bars & bushings","Four steel columns that join the platens, guide the moving platen and carry the clamping force. Tie bar nuts lock them in place; bushings guide the moving platen along them.",{"id":88,"number":70,"name":229,"role":230,"partCount":21},"Platens & mold plates","The fixed and moving platens carry the two halves of the mold; the rear platen anchors the toggle. Locating rings and clamping plates center and hold the mold.",{"id":232,"number":50,"name":233,"role":234,"partCount":50},"barrel-screw","Barrel, screw & nozzle","The screw turns inside the heated barrel to melt and mix the plastic, then moves forward to inject it through the nozzle into the mold. The screw tip and check ring stop melt from flowing back.",{"id":30,"number":79,"name":236,"role":237,"partCount":113},"Heater bands & sensors","Heater bands around the barrel and nozzle melt the plastic. Thermocouples measure each heating zone so the controller can hold the set temperature.",{"id":239,"number":84,"name":240,"role":241,"partCount":79},"injection-unit","Injection unit","Injection cylinders push the screw forward, the hydraulic (plasticizing) motor turns it, and the carriage moves the unit against the mold on its guide rails.",{"id":243,"number":244,"name":245,"role":246,"partCount":247},"hydraulics",9,"Hydraulic unit","The pump, motor, valves, accumulator, filters and oil cooler in the machine base. They supply and control the oil pressure for every movement of the machine.",16,{"id":8,"number":171,"name":249,"role":250,"partCount":244},"Electrical cabinet","The controller, I\u002FO and drive boards, servo drives, contactors and safety switches that run and protect the machine.",{"id":252,"number":10,"name":253,"role":254,"partCount":21},"feet","Machine feet","Leveling bolts and anti-vibration pads under the machine base that keep the machine level and stop vibration spreading to the floor.",{"parts":256,"subcategories":257},70,23,{"id":259,"title":260,"body":261,"description":511,"diagram":512,"extension":513,"faq":514,"item":527,"lastModified":528,"meta":529,"navigation":530,"order":50,"parts":531,"path":534,"seo":535,"seoTitle":536,"short":537,"stem":538,"__hash__":539},"guides\u002Finjection-molding-machine-parts\u002Fheaters\u002Freplacing-heater-bands.md","Replacing heater bands on an injection molding machine",{"type":262,"value":263,"toc":500},"minimark",[264,268,273,276,303,307,325,332,336,365,369,372,383,387,410,414,428,432,464,468,482],[265,266,267],"p",{},"Heater band replacement on an injection molding machine means isolating the zone, finding the failed band, loosening its clamp bolt, removing it from the barrel, cleaning the barrel surface and clamping a new band of the same size, power and voltage in its place. The clamp bolt, highlighted in the drawing, is the part that matters most: a band only works when it is tightened firmly and evenly against a clean barrel. When burnt plastic holds a band in place, a heater band removal tool helps free it without damage.",[269,270,272],"h2",{"id":271},"before-you-start","Before you start",[265,274,275],{},"Heater bands run on mains voltage and sit on a hot barrel. Follow your site's lockout procedure and the machine manual.",[277,278,279,288,291,294],"ul",{},[280,281,282,283,287],"li",{},"Switch off and ",[284,285,286],"strong",{},"lock off the heater supply",", and check the terminals are dead before touching them.",[280,289,290],{},"Let the barrel cool to a safe handling temperature, or follow your site's procedure if bands are changed warm. Wear heat-resistant gloves and eye protection.",[280,292,293],{},"Retract the injection unit and keep clear of the nozzle; plastic in the barrel can still be molten.",[280,295,296,297,302],{},"Have the replacement ready: same inside diameter, width, power, voltage and connection. See ",[298,299,301],"a",{"href":300},"\u002Finjection-molding-machine-parts\u002Fheaters\u002Fheater-band-types\u002F","heater band types",".",[269,304,306],{"id":305},"finding-the-failed-band","Finding the failed band",[308,309,310,313,316,319,322],"ol",{},[280,311,312],{},"On the temperature screen, find the zone that heats slowly or not at all while its output is high.",[280,314,315],{},"With the heaters on, check each band of that zone with a clamp meter on its cable. A band that draws no current while the output is on has failed or is not connected.",[280,317,318],{},"Isolate and lock off. Measure each band's resistance at its terminals. Compare with the value expected from its rating, R = V² \u002F P. An open circuit means a broken element.",[280,320,321],{},"Test the insulation resistance between each terminal and the band's shell. A low reading means the band leaks to earth and will trip the earth leakage protection.",[280,323,324],{},"Look at the band: burnt terminals, a swollen or cracked shell, or plastic underneath.",[265,326,327,328,302],{},"If the bands are good, look at the cable, the fuse, the relay and the thermocouple instead; see ",[298,329,331],{"href":330},"\u002Finjection-molding-machine-parts\u002Fheaters\u002Ftemperature-control\u002F","temperature control",[269,333,335],{"id":334},"removing-the-old-band","Removing the old band",[308,337,338,341,344,351,354,357],{},[280,339,340],{},"Photograph the wiring and note which terminal each cable goes to and which zone the band belongs to.",[280,342,343],{},"Open the terminal box and disconnect the cables.",[280,345,346,347,302],{},"Remove the thermocouple if it passes through the band or sits next to it, so it is not bent or pulled. See the ",[298,348,350],{"href":349},"\u002Finjection-molding-machine-parts\u002Fheaters\u002Fthermocouple\u002F","thermocouple guide",[280,352,353],{},"Loosen and remove the clamp bolt or bolts. Two-piece bands have a clamp on each side.",[280,355,356],{},"Open the band at its gap and lift it off the barrel. Do not lever it with a screwdriver against the barrel or bend the shell sharply.",[280,358,359,360,364],{},"If burnt plastic holds the band, warming the zone softens it. A ",[298,361,363],{"href":362},"\u002Fparts\u002Fmc-gmp-02\u002F","heater band removal tool"," helps free a stuck band without damaging it, and protects the band and its thermocouple connections when you remove and refit a band you are keeping.",[269,366,368],{"id":367},"preparing-the-barrel","Preparing the barrel",[265,370,371],{},"The new band transfers heat by contact, so the surface under it must be clean.",[277,373,374,377,380],{},[280,375,376],{},"Remove burnt plastic, scale and old residue from the barrel surface without scoring it.",[280,378,379],{},"Find and fix the source of any plastic under the band, usually a leak at the nozzle or the barrel front flange. Otherwise the new band will fail the same way.",[280,381,382],{},"Check the thermocouple hole is clear.",[269,384,386],{"id":385},"fitting-the-new-band","Fitting the new band",[308,388,389,392,395,398,401,404,407],{},[280,390,391],{},"Check the new band's label against the old one: inside diameter, width, power and voltage.",[280,393,394],{},"Open the band only as far as needed to slide it over the barrel, and place it in the same position as the old one, with the thermocouple hole aligned if it has one.",[280,396,397],{},"Turn it so the terminal box is accessible and the cable will not touch the barrel or moving parts.",[280,399,400],{},"Tighten the clamp bolt evenly until the band sits tight all around, without distorting the shell. On two-piece bands, tighten both sides a little at a time so the gaps stay even.",[280,402,403],{},"Reconnect the cables to the same terminals, using heat-resistant cable and terminals in good condition, and close the terminal box.",[280,405,406],{},"Refit the thermocouple fully into its hole.",[280,408,409],{},"Before switching on, measure the band's resistance and insulation once more.",[269,411,413],{"id":412},"after-the-first-heat-up","After the first heat-up",[308,415,416,419,422,425],{},[280,417,418],{},"Heat the zone and check that it heats and that its reading responds.",[280,420,421],{},"When it has reached temperature, re-tighten the clamp bolt, following your site's procedure for working near hot parts. New bands settle and expand on their first heat-up.",[280,423,424],{},"Compare the zone's reading with a handheld probe, and watch its output percentage over the next cycles.",[280,426,427],{},"If the zone overshoots or swings, run the controller's auto-tuning as described in the machine manual.",[269,429,431],{"id":430},"why-bands-fail-and-how-to-make-the-new-one-last","Why bands fail, and how to make the new one last",[277,433,434,440,446,452,458],{},[280,435,436,439],{},[284,437,438],{},"Loose clamp."," The air gap makes the element run hot. Check clamps at planned stops.",[280,441,442,445],{},[284,443,444],{},"Plastic under the band."," Fix leaks quickly and keep purged material away from the bands.",[280,447,448,451],{},[284,449,450],{},"Wrong voltage."," A band rated for a lower voltage than the supply burns out quickly.",[280,453,454,457],{},[284,455,456],{},"Damaged wiring."," Burnt terminals and brittle cable cause open circuits and shorts.",[280,459,460,463],{},[284,461,462],{},"Moisture."," Bands left in a damp place, or a machine stored for a long time, can show low insulation; follow the band maker's advice before powering them.",[269,465,467],{"id":466},"what-to-send-for-a-replacement-quote","What to send for a replacement quote",[308,469,470,473,476,479],{},[280,471,472],{},"The band's inside diameter and width, and its power and voltage.",[280,474,475],{},"The construction (ceramic or mica, one piece or two halves), the connection and the lead length.",[280,477,478],{},"Any thermocouple hole, and its position.",[280,480,481],{},"The machine brand and model, the zone, and a photo of the old band.",[265,483,484,485,489,490,494,495,499],{},"See the ",[298,486,488],{"href":487},"\u002Fparts\u002Fec-ht-01\u002F","ceramic heater bands"," we supply, then ",[298,491,493],{"href":492},"\u002Frequest-quote\u002F","request a quote",". The ",[298,496,498],{"href":497},"\u002Finjection-molding-machine-parts\u002Fheaters\u002F","heaters guide"," covers the rest of the heating system.",{"title":501,"searchDepth":21,"depth":21,"links":502},"",[503,504,505,506,507,508,509,510],{"id":271,"depth":21,"text":272},{"id":305,"depth":21,"text":306},{"id":334,"depth":21,"text":335},{"id":367,"depth":21,"text":368},{"id":385,"depth":21,"text":386},{"id":412,"depth":21,"text":413},{"id":430,"depth":21,"text":431},{"id":466,"depth":21,"text":467},"How to find a failed heater band on an injection molding machine, remove it with a heater band removal tool, fit and tighten the new band, and check the zone.",null,"md",[515,518,521,524],{"question":516,"answer":517},"How do I remove a heater band that is stuck to the barrel?","Isolate the power, fully loosen and remove the clamp bolt, and open the band at its gap. If burnt plastic holds it, warming the zone can soften the plastic, and a heater band removal tool helps free it without bending or tearing the band.",{"question":519,"answer":520},"Do heater bands need to be re-tightened?","Yes. A new band settles and expands on its first heat-up, so check and re-tighten the clamp bolts once the zone has reached temperature, following your site's procedure for working near hot parts. A loose band runs hot and fails early.",{"question":522,"answer":523},"How do I know which heater band has failed?","Look for the zone that heats slowly or not at all while its output is high. Confirm with a clamp meter on its cable, then isolate the power and measure each band's resistance and insulation.",{"question":525,"answer":526},"Can I fit a heater band with a different power?","Use the same power and voltage as the original unless the machine maker approves a change. A different power changes how the zone heats and can upset temperature control.","clamp","2026-11-01",{},true,[532,533],"EC-HT-01","MC-GMP-02","\u002Finjection-molding-machine-parts\u002Fheaters\u002Freplacing-heater-bands",{"title":260,"description":511},"Heater Band Replacement on an Injection Molding Machine","Replacing heater bands","injection-molding-machine-parts\u002Fheaters\u002Freplacing-heater-bands","9RvBkTWzt07U6mXh-csH2EiyNP9hxSOzee7wCuEidVQ",[541,545,549,553,557],{"path":542,"title":543,"short":544},"\u002Finjection-molding-machine-parts\u002Fheaters\u002Fheater-band-types","Heater band types for injection molding machines","Heater band types",{"path":546,"title":547,"short":548},"\u002Finjection-molding-machine-parts\u002Fheaters\u002Fnozzle-heater","Nozzle heater of an injection molding machine","Nozzle heater",{"path":550,"title":551,"short":552},"\u002Finjection-molding-machine-parts\u002Fheaters\u002Fthermocouple","Thermocouple of an injection molding machine","Thermocouple",{"path":554,"title":555,"short":556},"\u002Finjection-molding-machine-parts\u002Fheaters\u002Ftemperature-control","Barrel temperature control on an injection molding machine","Temperature control",{"path":558,"title":559,"short":560},"\u002Finjection-molding-machine-parts\u002Fheaters\u002Fbarrel-temperature-zones","Barrel temperature zones and temperature profile","Barrel temperature zones",{"diagram":562},"barrel-heating",{"diagram":564},{"title":565,"description":566,"base":567,"labels":571,"items":576},"Parts of barrel heating","Line drawing of an injection molding machine barrel with ceramic heater bands, terminal boxes, clamps, a cut-away band, thermocouples and the nozzle heater, numbered.",{"solid":568},[569,570],"M548 140h40a2 2 0 0 1 2 2v80a2 2 0 0 1 -2 2h-40a2 2 0 0 1 -2 -2v-80a2 2 0 0 1 2 -2z","M554 140L542 96L594 96L582 140Z",[572],{"x":573,"y":574,"text":575},568,88,"HOPPER",[577,592,605,619,643,694,712],{"id":578,"name":579,"role":580,"subcategory":67,"marker":581,"shapes":585},"barrel","Barrel","The steel barrel the screw turns in. Its heating zones run from the feed throat to the nozzle.",[582,583,582,584],108,336,216,{"solid":586,"hidden":590},[587,588,589],"M98 148h446a2 2 0 0 1 2 2v64a2 2 0 0 1 -2 2h-446a2 2 0 0 1 -2 -2v-64a2 2 0 0 1 2 -2z","M62 164h32a2 2 0 0 1 2 2v32a2 2 0 0 1 -2 2h-32a2 2 0 0 1 -2 -2v-32a2 2 0 0 1 2 -2z","M60 170L42 177L42 187L60 194Z",[591],"M104 166h436v32h-436z",{"id":593,"name":548,"role":594,"parts":595,"marker":596,"shapes":600},"nozzle-heater","A small band on the nozzle keeps the melt at temperature between shots.",[532],[597,598,597,599],80,24,156,{"solid":601,"line":603},[602],"M67 156h18a3 3 0 0 1 3 3v46a3 3 0 0 1 -3 3h-18a3 3 0 0 1 -3 -3v-46a3 3 0 0 1 3 -3z",[604],"M70 156L70 140",{"id":606,"name":607,"role":608,"parts":609,"marker":610,"shapes":613},"bands","Ceramic heater bands","Each band heats one zone of the barrel. The controller switches it on and off to hold the set temperature.",[532],[611,598,611,612],140,128,{"solid":614},[615,616,617,618],"M123 128h58a3 3 0 0 1 3 3v102a3 3 0 0 1 -3 3h-58a3 3 0 0 1 -3 -3v-102a3 3 0 0 1 3 -3z","M229 128h58a3 3 0 0 1 3 3v102a3 3 0 0 1 -3 3h-58a3 3 0 0 1 -3 -3v-102a3 3 0 0 1 3 -3z","M335 128h58a3 3 0 0 1 3 3v102a3 3 0 0 1 -3 3h-58a3 3 0 0 1 -3 -3v-102a3 3 0 0 1 3 -3z","M441 128h58a3 3 0 0 1 3 3v102a3 3 0 0 1 -3 3h-58a3 3 0 0 1 -3 -3v-102a3 3 0 0 1 3 -3z",{"id":620,"name":621,"role":622,"parts":623,"marker":624,"shapes":628},"terminal-box","Terminal box","Covers the band’s power terminals, where the heater cable connects.",[532],[625,598,626,627],190,160,114,{"solid":629,"line":634},[630,631,632,633],"M146 114h12a2 2 0 0 1 2 2v10a2 2 0 0 1 -2 2h-12a2 2 0 0 1 -2 -2v-10a2 2 0 0 1 2 -2z","M252 114h12a2 2 0 0 1 2 2v10a2 2 0 0 1 -2 2h-12a2 2 0 0 1 -2 -2v-10a2 2 0 0 1 2 -2z","M358 114h12a2 2 0 0 1 2 2v10a2 2 0 0 1 -2 2h-12a2 2 0 0 1 -2 -2v-10a2 2 0 0 1 2 -2z","M464 114h12a2 2 0 0 1 2 2v10a2 2 0 0 1 -2 2h-12a2 2 0 0 1 -2 -2v-10a2 2 0 0 1 2 -2z",[635,636,637,638,639,640,641,642],"M148 114L148 102","M156 114L156 102","M254 114L254 102","M262 114L262 102","M360 114L360 102","M368 114L368 102","M466 114L466 102","M474 114L474 102",{"id":644,"name":645,"role":646,"parts":647,"marker":648,"shapes":651},"ceramic","Ceramic blocks and coil","Inside the steel shell (cut away here), a resistance coil runs through ceramic blocks that hold it in place and insulate it.",[532],[649,583,649,650],240,233,{"solid":652,"line":685},[653,654,655,656,657,658,659,660,661,662,663,664,665,666,667,668,669,670,671,672,673,674,675,676,677,678,679,680,681,682,683,684],"M231 132h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M246 132h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M261 132h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M276 132h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M231 145h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M246 145h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M261 145h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M276 145h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M231 158h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M246 158h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M261 158h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M276 158h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M231 171h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M246 171h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M261 171h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M276 171h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M231 184h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M246 184h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M261 184h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M276 184h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M231 197h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M246 197h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M261 197h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M276 197h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M231 210h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M246 210h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M261 210h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M276 210h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M231 223h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M246 223h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M261 223h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z","M276 223h10a1 1 0 0 1 1 1v8a1 1 0 0 1 -1 1h-10a1 1 0 0 1 -1 -1v-8a1 1 0 0 1 1 -1z",[686,687,688,689,690,691,692,693],"M228 137L288 137","M228 150L288 150","M228 163L288 163","M228 176L288 176","M228 189L288 189","M228 202L288 202","M228 215L288 215","M228 228L288 228",{"id":527,"name":695,"role":696,"parts":697,"subcategory":98,"marker":698,"shapes":701},"Clamp bolt","Tightens the band against the barrel so the heat passes into it. A band removal tool helps free a band stuck to the barrel.",[532],[699,583,699,700],364,245,{"solid":702,"line":707},[703,704,705,706],"M143 236h18a1 1 0 0 1 1 1v7a1 1 0 0 1 -1 1h-18a1 1 0 0 1 -1 -1v-7a1 1 0 0 1 1 -1z","M249 236h18a1 1 0 0 1 1 1v7a1 1 0 0 1 -1 1h-18a1 1 0 0 1 -1 -1v-7a1 1 0 0 1 1 -1z","M355 236h18a1 1 0 0 1 1 1v7a1 1 0 0 1 -1 1h-18a1 1 0 0 1 -1 -1v-7a1 1 0 0 1 1 -1z","M461 236h18a1 1 0 0 1 1 1v7a1 1 0 0 1 -1 1h-18a1 1 0 0 1 -1 -1v-7a1 1 0 0 1 1 -1z",[708,709,710,711],"M138 241L166 241","M244 241L272 241","M350 241L378 241","M456 241L484 241",{"id":713,"name":714,"role":715,"parts":716,"marker":718,"shapes":721},"thermocouples","Thermocouples","Sensors set into the barrel wall between the bands. The controller reads each one to switch its zone.",[717],"EC-HT-02",[719,598,719,720],311,98,{"solid":722,"line":726,"hidden":733},[723,724,725],"M201 98h8a2 2 0 0 1 2 2v14a2 2 0 0 1 -2 2h-8a2 2 0 0 1 -2 -2v-14a2 2 0 0 1 2 -2z","M307 98h8a2 2 0 0 1 2 2v14a2 2 0 0 1 -2 2h-8a2 2 0 0 1 -2 -2v-14a2 2 0 0 1 2 -2z","M413 98h8a2 2 0 0 1 2 2v14a2 2 0 0 1 -2 2h-8a2 2 0 0 1 -2 -2v-14a2 2 0 0 1 2 -2z",[727,728,729,730,731,732],"M205 116L205 148","M211 104L223 104","M311 116L311 148","M317 104L329 104","M417 116L417 148","M423 104L435 104",[734,735,736],"M205 148L205 162","M311 148L311 162","M417 148L417 162",[738,745],{"partNumber":532,"name":739,"subcategory":28,"subcategoryName":29,"shortDescription":740,"inStock":530,"zone":30,"compatibleMachines":741},"Ceramic Heater Band","Full-enclosed ceramic heater band for injection molding machine barrel and nozzle heating zones.",[742,743,744],"Haitian MA Series","Haitian MA II Series","Haitian Jupiter Series",{"partNumber":533,"name":746,"subcategory":98,"subcategoryName":747,"shortDescription":748,"image":749,"inStock":530,"zone":30,"compatibleMachines":750},"Barrel Heating Band Removal Tool","Maintenance Tools","Specialized tool for removing and installing heater bands on injection molding machine barrels.","\u002Fpart-images\u002FMC\u002FMC-GMP-02\u002Fe3443cd0-195f-44da-a410-8e85809efc0a.png",[742,751],"Various injection molding machines",1793548981743]